Page 169 - IS-Rayfast Catalogue - Issue 9, 2017
P. 169
Braided Sleeving
®
ROUNDIT EMI FMJ
PPS Mono-filaments and Cu/Ni Wire
Self-wrapping electromagnetic shielding
Properties Test Results 1
Rapid change of temperature EN2591-305 Pass
ABD 031 & FAR 25 § 853 Conforms 2
Flammability / Smoke / Toxicity NF 16101 & 16102 I3 F0
EN 45545-2 R22 HL3 R23 HL3
3
Dynamic cut-through EN 6059 Part 405 Pass
Hard Vacuum ASTM E-595 Meets standards
4
Fluid resistance
• Jet fuel: JP4 (NATO F44)
• Hydraulic fluid: Skydrol 500 B4
• Mineral oil: MIL-L-7870A EN 6059-303 Pass 5
• Synthetic oil: MIL-L-23699
• Cleaning fluids: MIL-L-87936
• De-icing fluid: MIL-A-8243 6
Salt spray resistance EN 2591-307 for 96 hours Pass
7
Mould growth EN 6059 Part 306 Pass
App. Range Weight Pack Size EMI Performance 8
Part Number
Min. (mm) Max (mm) g/m Spools (m) Ro max size 8 - 5.5 mΩ
Resistance Measurement EN 3475-301
Ro max other sizes - 5 mΩ
1.0 5.0 30 250 ROUNDIT-EMI-FMJ-5mm-8* 9
IEC 62153-4-3 Triaxial method on
5.0 8.0 40 250 ROUNDIT-EMI-FMJ-8mm-8 Transfer Impedance Lt = 0.6 nH
straight installation
8.0 13.0 60 175 ROUNDIT-EMI-FMJ-13mm-8
Lightning EN 2591-214 - Waveform 1 10KA Pass 10
13.0 19.0 85 125 ROUNDIT-EMI-FMJ-19mm-8
19.0 25.0 107 75 ROUNDIT-EMI-FMJ-25mm-8 11
Transfer Impedence Measurement
25.0 32.0 144 50 ROUNDIT-EMI-FMJ-32mm-8
32.0 38.0 169 35 ROUNDIT-EMI-FMJ-38mm-8
12
* Size 5 is designed for cross-talk applications and complies with a maximum R0 at 8mΩ and a Lt at 1.3
nH. This is delivered with a white ivory line for maximum operating diameter identification. Lightening strike
exposure upon request. 13
Standard Colour: 8 Light grey
14
15
16
17
18