Page 171 - IS-Rayfast Catalogue - Issue 9, 2017
P. 171
Braided Sleeving
®
ROUNDIT EMI C* XWS
PPS Mono-filaments and Cu/Ni Wire
Self-wrapping electromagnetic shielding
Properties Test Results 1
Rapid change of temperature EN6059-308 Pass
Flammability / Smoke / Toxicity ABD 031 & FAR 25 § 853 Conforms 2
Dynamic cut-through EN 6059 Part 405 Pass
Bending EN 6059 Part 402 Pass 3
Vibrations EN 6059 Part 406 Pass
Fluid resistance 4
• Jet fuel: JP4 (NATO F44)
• Hydraulic fluid: Skydrol 500 B4
• Mineral oil: MIL-L-7870A EN 6059-303 Good resistance 5
• Synthetic oil: MIL-L-23699
• Cleaning fluids: MIL-L-87936
• De-icing fluid: MIL-A-8243
6
C4: EN 2591-307 for 96 hours
Salt spray resistance Pass
C27: EN 2591-307 for 500 hours
7
Mould growth EN 6059 Part 306 Pass
App. Range Max. Weight Pack Size EMI Performance 8
Part Number
Min. (mm) Max (mm) C4 (g/m) C27 (g/m) Spools (m) Ro max = 5 mΩ all sizes except
Resistance Measurement EN 3475-301
1.0 5.0 50 59 200 ROUNDIT-EMI-C*-XWS-B-5-8 size 5 = 6 mΩ 9
5.0 8.0 54 66 150 ROUNDIT-EMI-C*-XWS-B-8-8 Transfer Impedance IEC 62153-4-3 Triaxial method Lt = 2 nH Pass
8.0 13.0 67 77 125 ROUNDIT-EMI-C*-XWS-B-13-8 EN 2591-214 10
Lightning C4: Waveform 1 5KA Pass
13.0 16.0 72 82 75 ROUNDIT-EMI-C*-XWS-B-16-8
C27: Waveform 1 10KA
16.0 19.0 93 96 75 ROUNDIT-EMI-C*-XWS-B-19-8
11
19.0 25.0 122 122 75 ROUNDIT-EMI-C*-XWS-B-25-8
25.0 32.0 160 160 50 ROUNDIT-EMI-C*-XWS-B-32-8
12
32.0 38.0 187 187 35 ROUNDIT-EMI-C*-XWS-B-38-8
38.0 45.0 205 205 35 ROUNDIT-EMI-C*-XWS-B-45-8
13
* Denotes that either C4 or C27 should be stated
Larger sizes up to 165mm are available in C27 sleeving, made up by assembling two together without the inner
PTFE layer, please contact us for more information. 14
15
16
17
18
sales@is-rayfast.com 169