Page 26 - IS-Rayfast Catalogue - Issue 9, 2017
P. 26

Wire and Cable
      55 Wire
      Single or Dual Wall 200ºC rated, XLETFE
      High performance wire and cable

  1   600V Primary Wire, Equipment/Interconnect Dimensions
       Conductor   Stranding  Nominal CSA  Nominal Dia.  Max Weight   Ordering
                                    2
  2      Size       No/mm        (mm )        (mm)        (g/m)      Description
          30        7/0.10       0.06         0.61         0.98     55A0111-30-X
          28        7/0.13       0.09         0.68         1.35     55A0111-28-X
  3
          26        19/0.10      0.16         0.81         2.08     55A0111-26-X
          24        19/0.13      0.24         0.94         2.98     55A0111-24-X
  4
          22        19/0.16      0.38         1.09         4.17     55A0111-22-X
          20        19/0.20      0.62         1.27         6.40     55A0111-20-X
  5
          18        19/0.25      0.96         1.52         9.67     55A0111-18-X
          16        19/0.29      1.23         1.73        12.35     55A0111-16-X
  6
          14        19/0.36      1.94         2.16        19.34     55A0111-14-X
          12        37/0.32      2.97         2.62        29.32     55A0111-12-X
  7


  8   600V Primary Wire, Airframe Dimensions
        Conductor     Stranding     Nominal Dia.    Max Weight      Ordering
          Size         No/mm           (mm)           (g/m)        Description
  9
            26*        19/0.10         1.01            2.53        55A0814-26-X
            24*        19/0.13         1.14            3.42        55A0814-24-X
  10
           22          19/0.16         1.27            4.76        55A0811-22-X
           20          19/0.20         1.47            6.99        55A0811-20-X
  11
           18          19/0.25         1.78           10.71        55A0811-18-X
           16          19/0.29         1.96           13.39        55A0811-16-X
  12       14          19/0.36         2.40           20.54        55A0811-14-X
           12          37/0.32         2.82           30.51        55A0811-12-X
  13       10          37/0.40         3.40           48.22        55A0811-10-X
           08          133/0.29        4.20           89.72        55A0811-08-X
  14   Note*: Conductor type Silver plated high strength copper alloy (SPHSCA).


  15 450V Primary Wire, Light Weight Equipment Dimensions
        Conductor     Stranding     Nominal Dia.    Max Weight      Ordering
  16      Size         No/mm           (mm)           (g/m)        Description
           30           7/0.10         0.51            0.87        55M0414-30-X
           28           7/0.12         0.58            1.19        55M0414-28-X
  17
           26          19/0.10         0.69            1.80        55M0414-26-X
           24          19/0.12         0.81            2.68        55M0414-24-X
  18
       Note: 55M0414 constructions are ideally suited for the performance demands of the Motorsport industry.


     24            sales@is-rayfast.com  |  +44(0)1793 616700