Page 28 - IS-Rayfast Catalogue - Issue 9, 2017
P. 28
Wire and Cable
55 Wire
Single or Dual Wall 200ºC rated, XLETFE
High performance wire and cable
1 600V Single Core Screened & Jacketed, Equipment/Interconnect
Conductor Stranding Nominal Dia. Max Weight Ordering
2 Size No/mm (mm) (g/m) Description
30 7/0.10 1.45 5.06 55A1111-30-X-X
28 7/0.13 1.52 5.80 55A1111-28-X-X
3
26 19/0.10 1.65 6.84 55A1111-26-X-X
24 19/0.13 1.78 8.20 55A1111-24-X-X
4
22 19/0.16 1.93 10.33 55A1111-22-X-X
20 19/0.20 2.13 13.40 55A1111-20-X-X
5
18 19/0.25 2.39 17.86 55A1111-18-X-X
16 19/0.29 2.59 21.73 55A1111-16-X-X
6
14 19/0.36 3.02 30.36 55A1111-14-X-X
12 37/0.32 3.48 42.41 55A1111-12-X-X
7
8 600V Single Core Screened & Jacketed, Airframe
Conductor Stranding Nominal Dia. Max Weight Ordering
Size No/mm (mm) (g/m) Description
9
26* 19/0.10 1.85 7.88 55A1814-26-X-X
24* 19/0.13 1.98 9.37 55A1814-24-X-X
10
22 19/0.16 2.13 11.75 55A1811-22-X-X
20 19/0.20 2.34 14.88 55A1811-20-X-X
11
18 19/0.25 2.62 19.79 55A1811-18-X-X
16 19/0.29 2.82 23.81 55A1811-16-X-X
12 Note*: Conductor type Silver plated high strength copper alloy (SPHSCA).
13
450V Single Core Screened & Jacketed, Light Weight Equipment
14
Conductor Stranding Nominal Dia. Max Weight Ordering
Size No/mm (mm) (g/m) Description
15 30 7/0.10 1.17 3.61 55M1414-30-X-X
28 7/0.12 1.24 4.12 55M1414-28-X-X
16 26 19/0.10 1.34 4.92 55M1414-26-X-X
24 19/0.12 1.47 6.50 55M1414-24-X-X
17 Note: 55M1414 constructions are ideally suited for the performance demands of the Motorsport industry.
18
26 sales@is-rayfast.com | +44(0)1793 616700