Page 368 - IS-Rayfast Catalogue - Issue 9, 2017
P. 368

Backshells
      Determine Entry Size




  1   Determining the Entry Size            If the adaptor is shielded or has a Tinel-Lock
      Once you have the wire bundle size, use the   ring, there are additional considerations, which
      chart below to select entry size. Chart shows   are noted below.
  2   the minimum entry sizes for cables from 3 to
      38 mm  in diameter. In other words, the white   For further information or assistance on
      spaces on the chart represent all of the cable   selecting the correct entry size or constructing
  3   outside diameters each entry size will fit.  your required adaptor part number, please
                                            contact us.
      Follow these steps:
  4
       •  Find the cable diameter on the chart.
       •  Please note the lowest entry size that will
         fit the cable diameter.
  5

  6     24
        22
        20
  7     18
        16
  8    Entry size  14
        12
        10
        08
  9
        07
        06
  10    05
        04
          3  4  5  6  7  8  9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38
  11

  12  Braided Tail Backshells               Memory Ring Backshells
      The extreme flexibility of the braid on these   The cable braid must be opened up to fit onto
      backshells accommodates a large range of   the outside diameter of the adaptor entry. For
  13 cable diameters. It is therefore recommended   optimum performance, select the smallest
      that the standard entry size for any given   entry size that will pass over the jacketed cable
      adaptor part number be specified as indicated   diameter. Repair of the connector will be easier
  14 on the relevant data sheet. Non standard   using the boot and shield rollback if a slightly
      entry sizes are available to special order. Use   larger than minimum entry size is used.
      the selection chart above to ensure that the   The selection chart above shows the minimum
  15  standard entry size will pass over the jacketed   entry sizes for cable diameters in the range of 3
      cable diameter.
                                            mm to 38 mm. This will ensure that the jacketed
  16                                        cable passes through the adaptor. Ensure the
                                            braid will open sufficiently to fit the entry size
                                            selected and to ensure that the braid and boot
  17                                        can be rolled back.


  18