Page 76 - IS-Rayfast Catalogue - Issue 9, 2017
P. 76

Wire and Cable
      Def Stan 61-12 (part 25)
      Zerohal Marine Cables                                                 A
      Limited Fire Hazard

  1   IS-Group offer a comprehensive portfolio of
      high performance cables designed for today’s
      modern range of warships and submarines.
  2
      Zerohal Marine Cables
      The cables briefly described over these two
  3
      pages are manufactured and approved to
                                           HALOGEN
      UK Defence Standard 61-12 (Part 25) and   FREE
  4   have been widely adopted as the basis for
      lightweight Limited Fire Hazard (LFH) cables
                                           LFH
      by the UK Navy and many other Navies
  5   worldwide. Limited Fire Hazard Cables are   Low Fire
      designed to minimise the risk associated with   Hazard
      the generation of smoke and toxic fumes
  6   during a fire.
                                                                            B
      Def Stan 61-12 (Part 25) Spec Summary
  7
      Cables manufactured and approved to Def
      Stan 61-12 (part 25) use component wires and
  8   cable jackets approved to specifications which
      independently impose performance limits on
      the generation of smoke and fumes in fire.
  9   Def Stan 61-12 (Part 25) cables employ;
       •  Component wires approved to Def Stan
         61-12 (Part 18). Within this specification,
  10                                       FREE
                                           HALOGEN
         wires are categorised as Type 1 pliable,
         or Type 2 non-pliable. Component wires
  11     99M0111 are Type 1, pliable wires.  LFH
       •  Jacket material is approved to Def Stan
                                           Low Fire
         61-12 (Part 31) (Limited Fire Hazard   Hazard
  12     Sheathing for Electric Cables). Zerohal
         jacket material is fully approved to this
         specification.                                                     C
  13
      Def Stan 61-12 (Part 25) details a number of
      specific cable constructions. Alternative cable
  14
      constructions utilising optional component
      layout or specialised shielding are available
  15  on request. Alternative constructions use
      approved wires and jackets and will meet the
      full performance requirements of Def Stan
  16 61-12 (Part 25).
                                           HALOGEN
      Other LFH Specification Approvals    FREE
  17
       •  MSV 34411, 34412, 34430, 34435, 34436
         (Netherlands)                     LFH
  18   •  Mil-C-24640, PMS 400 (USA)       Low Fire