Page 82 - IS-Rayfast Catalogue - Issue 9, 2017
P. 82

Wire and Cable
      Custom Cable Designs
      2. Cable Jacket Selection
      Multi-conductor cables

  1   There is an unrivalled selection of medium
      to high performance cable jacket materials
      covering a wide operating temperature range,
  2   for various applications.
      We offer the unique choice of a cross-linked
      heat-shrink jacket for short run and prototype
  3
      cables or an extruded jacket for larger scale
      production requirements. In both cases, the
  4   combination of the right primary wire with a
      matched cable jacket will produce the optimum
      solution for your specific cable application.
  5


  6   2a. HEAT-SHRINK Jacket Selection Prototype Cables
                     Temperature   Chemical   Abrasion   Flexibility  Typical Application
  7                   Range ºC  Resistance  Resistance
                                                             Aerospace, Industrial
       PTFE          -67 to +250  Excellent  Good     Fair
                                                             Sensors, Thermocouples
  8
                                                             Military, Aerospace,
       RW-200-E      -55 to +200  Very Good  Good    Good
                                                             Industrial
  9    DR-25         -75 to +150  Very Good  Fair   Very Good  Aerospace, Autosport,
                                                             Military
                                                             Military, Industrial,
       RNF-100       -55 to +135  Good      Good     Good
  10                                                         Commercial
                                                             Marine, Rail and Mass
       ZHTM          -30 to +105  Fair      Good     Good
                                                             Transit
  11                                                         General Purpose,
       VERSAFIT      -55 to +135  Fair      Fair     Good
                                                             Commercial
  12
      2b. EXTRUDED Jacket Selection Production Cables
  13
                     Temperature   Chemical   Abrasion   Flexibility  Typical Application
                      Range ºC  Resistance  Resistance
  14                                                         Aerospace, Industrial
       PTFE          -67 to +260  Excellent  Good     Fair
                                                             Sensors, Thermocouples
                                                             Instrumentation, Industrial,
  15   FEP           -65 to +200  Excellent  Good    Good    Commercial
                                                             Aerospace, Autosport,
       FDR 25        -40 to +150  Very Good  Fair   Very Good  Military
  16
                                                             Military, Industrial,
       THERMORAD     -55 to +125  Good      Good     Good
                                                             Commercial
  17   ZEROHAL       -30 to +105  Good      Good     Good    Marine, Rail and Mass
                                                             Transit
                                                             General Purpose,
  18   POLYURETHANE  -25 to +80   Fair      Fair    Very Good  Commercial


     80            sales@is-rayfast.com  |  +44(0)1793 616700
   77   78   79   80   81   82   83   84   85   86   87