Page 276 - IS-Rayfast Catalogue - Issue 9, 2017
P. 276

Terminals and Splices
      Shielded Connector Contacts
      SolderTacts ®
      Controlled Solder Contacts

  1   One-piece controlled soldering SolderTacts
      are designed to facilitate faster and more
      reliable terminations. SolderTacts eliminate the
  2   variables associated with crimping, accelerates
      production while reducing handling and
      installed costs.
  3
      Features & Benefits
       •  One-piece contact design with integrated
  4
         soldering technology
       •  Controlled re-flow soldering process yields
         reliable consistent terminations
  5
       •  360º shielding reduces crosstalk and
         improves signal transmission.
  6    •  Contact fits multiple cable sizes.  Specifications & Approvals
       •  Compatible with a variety of commercial   •  TE D-6002
         and military connectors.
  7    •  150ºC temperature rating.


  8
            1           2                3                     4
  9


  10

  11            5                       6   7                       8

  12 1. Outer SolderSleeve                  5. Outer Solder Pre-form
      Heat shrinkable insulating sleeve. Cable inserts   Contains precise amounts of solder and flux
      easily, with no spacers or other parts required.  conforming to QQ-S-571.
  13
      2. Inner SolderSleeve                 6. Inner Pin and Socket
      Termination is a heat shrinkable sleeve with a   Contacts are permanently fixed within the
  14  precisely pre-fluxed solder preform conforming   assembly to provide proper setback and
      to QQ-S-571                           concentrically.
  15
      3. Connector                          7. Dielectric
      The precision outer body meets electrical   The dielectric between inner and outer contacts
  16  engagement and contact retention      provides concentricity, electrical integrity,
      requirements of individual connector systems.  precise mating dimensions and closed entry at
                                            the inner socket.
  17 4. Inner Heat shrink
      In the terminated signal lead, the inner   8. Inspection
      heat shrink tubing forms tightly around the   The shield termination can be inspected
  18 termination to insulate and strain relieve the   through the viewing port.
      connection.