Page 46 - IS-Rayfast Catalogue - Issue 9, 2017
P. 46
Wire and Cable
SAE AS22759 • M22759
Equipment Wire
Military and Commercial Aerospace
1 M22759/5 to /12 Extruded PTFE Insulation
M27500 Conductor Temp. Volt.
Reference Insulation AWG
2 Identifier Plating Rating Rating
M22759/5 VA Silver Extruded PTFE* 200ºC 600 V 24 to 20
M22759/6 WA Nickel Extruded PTFE* 260ºC 600 V 24 to 20
3
M22759/7 SA Silver Extruded PTFE* 200ºC 600 V 24 to 8
M22759/8 TA Nickel Extruded PTFE* 260ºC 600 V 24 to 8
4
M22759/9 LE Silver Extruded PTFE 200ºC 1000 V 28 to 10
M22759/10 LH Nickel Extruded PTFE 260ºC 1000 V 28 to 8
5
M22759/11 RC Silver Extruded PTFE 200ºC 600 V 28 to 8
M22759/12 RE Nickel Extruded PTFE 260ºC 600 V 28 to 8
6 * Denotes mineral filled PTFE insulation
7
8 M22759/13 to /15 Extruded FEP Insulation, with PVDF outer
M27500 Conductor Temp. Volt.
Reference Insulation AWG
Identifier Plating Rating Rating
9
M22759/13 CA Tin Extruded FEP/PVDF 135ºC 600 V 24 to 10
M22759/14 CB Tin Extruded FEP/PVDF 135ºC 600 V 26 to 12
10
M22759/15 CC Silver HSCA Extruded FEP/PVDF 135ºC 600 V 26 to 20
11
12 M22759/16 to /19 Extruded ETFE Insulation
M27500 Conductor Temp. Voltage
Reference Insulation AWG
13 Identifier Plating Rating Rating
M22759/16 TE Tin Extruded ETFE 150ºC 600 V 24 to 00
14 M22759/17 TF Silver HSCA Extruded ETFE 150ºC 600 V 26 to 20
M22759/18 TG Tin Extruded ETFE 150ºC 600 V 26 to 10
M22759/19 TH Silver HSCA Extruded ETFE 150ºC 600 V 26 to 20
15
16
17
18