Page 41 - IS-Rayfast Catalogue - Issue 9, 2017
P. 41
Wire and Cable
100E Wire
Halogen Free, Low Smoke
Fire Hazard Properties and Part Numbering
EN50306-4 Multi-Core and Multi-Pair Cables, 1
Screened and Standard Wall Sheathed
Conductor Finished Wire
Custom designed cables (specials). Due to the 2
Cross
Shield Jacket Thickness Nom. Overall Max. potential number of parts possible, these will
Part Description Sectional Size Min. Nom. Diameter Weight be created as EPD cables. Rail specifications
Area
EN50306-4 multi-core and multi-pair cables are 3
100E1121-0.50-X 0.50 mm 2 0.13 mm 0.20 mm 0.38 mm 4.14 mm 32.5 kg/km standard wall sheathed.
100E1121-0.75-X 0.75 mm 2 0.13 mm 0.20 mm 0.38 mm 4.56 mm 39.0 kg/km
• Unscreened, sheathed for either exposed 4
100E1121-1.00-X 1.00 mm 2 0.13 mm 0.20 mm 0.38 mm 4.81 mm 47.0 kg/km
2
2
or protected wiring (0.5mm to 2.50 mm ,
100E1121-1.50-X 1.50 mm 2 0.13 mm 0.20 mm 0.38 mm 5.48 mm 64.4 kg/km number of cores from 2 to 48). Conforms
100E1121-2.50-X 2.50 mm 2 0.13 mm 0.20 mm 0.38 mm 6.48 mm 95.2 kg/km with table 1 of EN50306-4 (Class 1P or 1E) 5
• Screened, sheathed for either exposed
or protected wiring (0.5mm to 2.50 mm , 6
2
2
number of cores from 2 to 8). Conforms
with table 3 of EN50306-4 (Class 3P or 3E)
• Screened, sheathed for either exposed 7
2
or protected wiring (0.5mm to 1.50 mm ,
2
number of cores from 2 to 7). Conforms
with table 3 of EN50306-4 (Class 5P or 5E) 8
9
10
11
12
13
14
15
16
17
18
www.is-rayfast.com 39