Page 41 - IS-Rayfast Catalogue - Issue 9, 2017
P. 41

Wire and Cable
                                                                     100E Wire
                                                            Halogen Free, Low Smoke
                                               Fire Hazard Properties and Part Numbering

       EN50306-4 Multi-Core and Multi-Pair Cables,                                1
       Screened and Standard Wall Sheathed
 Conductor  Finished Wire
       Custom designed cables (specials). Due to the                              2
 Cross
 Shield  Jacket Thickness  Nom. Overall   Max.  potential number of parts possible, these will
 Part Description  Sectional   Size  Min.            Nom.  Diameter  Weight  be created as EPD cables. Rail specifications
 Area
       EN50306-4 multi-core and multi-pair cables are                             3
 100E1121-0.50-X  0.50 mm  2  0.13 mm  0.20 mm  0.38 mm  4.14 mm  32.5 kg/km  standard wall sheathed.
 100E1121-0.75-X  0.75 mm  2  0.13 mm  0.20 mm  0.38 mm  4.56 mm  39.0 kg/km
        •  Unscreened, sheathed for either exposed                                4
 100E1121-1.00-X  1.00 mm  2  0.13 mm  0.20 mm  0.38 mm  4.81 mm  47.0 kg/km
                              2
                                       2
          or protected wiring (0.5mm  to 2.50 mm ,
 100E1121-1.50-X  1.50 mm  2  0.13 mm  0.20 mm  0.38 mm  5.48 mm  64.4 kg/km  number of cores from 2 to 48). Conforms
 100E1121-2.50-X  2.50 mm  2  0.13 mm  0.20 mm  0.38 mm  6.48 mm  95.2 kg/km  with table 1 of EN50306-4 (Class 1P or 1E)  5
        •  Screened, sheathed for either exposed
          or protected wiring (0.5mm  to 2.50 mm ,                                6
                                       2
                              2
          number of cores from 2 to 8). Conforms
          with table 3 of EN50306-4 (Class 3P or 3E)
        •  Screened, sheathed for either exposed                                  7
                                       2
          or protected wiring (0.5mm  to 1.50 mm ,
                              2
          number of cores from 2 to 7). Conforms
          with table 3 of EN50306-4 (Class 5P or 5E)                              8
                                                                                  9
                                                                                 10

                                                                                 11

                                                                                 12


                                                                                 13

                                                                                 14

                                                                                 15


                                                                                 16

                                                                                 17


                                                                                 18