Page 270 - IS-Rayfast Catalogue - Issue 9, 2017
P. 270

Terminals and Splices
      PCB Coaxial Termination
      SolderSleeve ®
      Heat Shrinkable, termination

  1   Used for the termination of coaxial cable to
      printed circuit boards.
  2   Features & Benefits
       •  Provides a completely shielded, low-
         resistance, matched-impedance
  3      termination with  a very low Voltage
         Standing Wave Ratio (D-607 series).
       •  Polyvinylidene fluoride or polyolefin
  4
         insulation sleeve provides encapsulation,
         inspectability, strain relief and insulation.
       •  Pre-fluxed solder preform provides
  5
         controlled soldering process.
       •  One piece design provides easy
  6      installation and lower installed costs.  Specifications & Approvals
       •  Pre-installed termination body provides   •  TE Connectivity RT-1404
         convenience and ease of installation.
  7
      Product Options
  8   Product Series  Typical Application Performance  Shield Method  Part Selection Table
      D-607        Matched impedance up to 2.3 GHz  Metal body         A
  9   B-046        Effective transmission up to 100 MHz  Pin to ground  B


  10
      Product Selection Process
                                              A              B              C              D
       1  Select product series from the Product
         Options table above.
  11
       2  Determine cable RG number or outside
         diameter dimensions.
  12   3  Select the appropriate part number from
         Table A (D-607 series) or Table B (B-046
         series).
  13   •  For D-607 (matched impedance) series,
         determine straight or right angle entry
         to PCB and grid pattern, then select the
  14     appropriate part number from Table A on
         the next page.
  15   •  For B-046 (PinPak, or pin to ground)
         series, determine hole spacing and
         diameter. Refer to Table B for product
  16     selection (see illustration right for cable
         dimensions).
  17

      Notes:
  18   •  Heat guns are recommended for the installation of these devices: HL2010E and CV198X with the correct
         reflector added. See Application Equipment Section.


    268            sales@is-rayfast.com  |  +44(0)1793 616700