Page 35 - IS-Rayfast Catalogue - Issue 9, 2017
P. 35
Wire and Cable
99M Wire
Dual Wall 120ºC rated wire, Modified Polyester
Low fire hazard wire and cable
600V Primary Wire Dimensions (all dimensions are in mm) 1
Conductor Stranding Nominal CSA Nominal Dia. Max Weight Ordering
2
Size No/mm (mm ) (mm) (g/m) Description
2
28 7/0.12 0.09 0.72 1.50 99M0111-28-0
26 19/0.10 0.15 0.90 2.18 99M0111-26-0
3
24 19/0.12 0.25 0.98 3.45 99M0111-24-0
22 19/0.15 0.40 1.13 4.90 99M0111-22-0
4
20 19/0.20 0.60 1.40 7.56 99M0111-20-0
18 19/0.25 1.00 1.65 10.40 99M0111-18-0
5
16 19/0.30 1.25 1.90 16.50 99M0111-16-0
14 37/0.25 2.00 2.25 20.70 99M0111-14-0
6
12 37/0.30 3.00 2.60 27.10 99M0111-12-0
7
600V Single Core Screened & Jacketed Dimensions (all dimensions are in mm)
Conductor Stranding Nominal Dia. Max Weight Ordering 8
Size No/mm (mm) (g/m) Description
26 19/0.10 1.80 8.29 99M1111-26-X-0
9
24 19/0.12 1.90 9.80 99M1111-24-X-0
22 19/0.15 2.05 12.00 99M1111-22-X-0
10
20 19/0.20 2.30 16.00 99M1111-20-X-0
18 19/0.25 2.55 21.30 99M1111-18-X-0
11
16 19/0.30 2.95 29.20 99M1111-16-X-0
14 37/0.25 3.13 34.80 99M1111-14-X-0
12 37/0.30 3.48 43.10 99M1111-12-X-0 12
13
600V 2-Core Screened & Jacketed Dimensions (all dimensions are in mm)
Conductor Stranding Nominal Dia. Max Weight Ordering
Size No/mm (mm) (g/m) Description 14
28 7/0.10 2.49 11.66 99M1121-28-X/X-0
26 19/0.10 2.79 15.82 99M1121-26-X/X-0 15
24 19/0.12 2.99 17.82 99M1121-24-X/X-0
22 19/0.15 3.29 22.11 99M1121-22-X/X-0 16
20 19/0.20 3.84 30.04 99M1121-20-X/X-0
18 19/0.25 4.34 38.14 99M1121-18-X/X-0 17
16 19/0.30 4.84 52.91 99M1121-16-X/X-0
14 37/0.25 5.54 64.86 99M1121-14-X/X-0
18
12 37/0.30 6.24 81.38 99M1121-12-X/X-0
www.is-rayfast.com 33