Page 36 - IS-Rayfast Catalogue - Issue 9, 2017
P. 36

Wire and Cable
      100 Wire
      Halogen Free, Low Smoke
      Introduction

  1   Range of high performance wire and cable that
      meet the demanding requirements of various
      standards including German Specification
  2   VG 95218-20 (100G wire) and European Rail   HALOGEN
      standard EN50306 (100E wire).        FREE
      Characteristics include being extremely flexible,
  3
      tough and resistant to a variety of fluids meeting   LFH
      the limited fire hazard requirements. Insulation
                                           Low Fire
      materials are mechanically strong and durable   Hazard
  4
      whilst being smaller and lighter.
      Zero Halogen, light weight wire and cable for   RoHS
  5   signal and equipment wire for low voltage   compliant
      applications.
      The construction is a dual wall combination of
  6                                         50% Volume Reduction
      formulated polymer blends. Developed to meet
                                            30% Weight Reduction
      demanding specification requirements, whilst
  7   maintaining the desirable features of small size,   Compared to conventional wire
      lightweight, flexibility and non-wrinkling.
                                               100 Wire           Conventional Wire
  8   Product Features                           15mm                22mm
       •  Zero halogen, thin wall, high temperature                 22mm
       •  Small size and lightweight             15mm
  9
       •  Excellent handling and flexibility
       •  Outstanding resistance to oils, plus scrape
  10     abrasion and cut through.     9mm                                       14mm
       •  Voltage rating: 300V and 750V.
  11   •  Conductor cores 0.5mm  to 2.5mm .
                                   2
                           2
       •  Continuous operating temperature:    100E Wire      Conventional Wire
                                                      2
  12     Wire; -55ºC to +125C                  35 x 1mm  wires > 50% reduction in bulk
         Cable: -30ºC to +105ºC                 of wiring and > 30% reduction in the
                                                        weight of wiring
       •  Dual wall construction
  13
      100E Wire Approvals                   Conventional cables use filled soft polymer
                                            insulations, which by the nature of the
      EN50306-2 Thin wall single core wires, 300
  14                                        insulation have to be thick wall. 100E wire uses
      volts.
                                            engineered polymers to greatly reduce wall
      EN50306-3 Single core and multi-core cables   thickness by ~5 times.
  15 (pairs, triples and quads) screened and thin wall
      sheathed.
      EN50306-4 Multi-core and Multi-pair
  16
      cables standard wall sheathed, screened or
      unscreened (thicker outer jacket).
  17
      100G Wire Approvals
      Meets requirements of VG 95218-20 Type E
  18  primary wire.