Page 39 - IS-Rayfast Catalogue - Issue 9, 2017
P. 39
Wire and Cable
100E Wire
Halogen Free, Low Smoke
Fire Hazard Properties and Part Numbering
100E Fire Hazard Properties 1
Test Method Result Test Method Result
2
Toxicity Def. Standard 02-713 3.5 Flame Propagation - Single cable IEC 60332-1-2 Charring confined 50-540mm
Smoke Density IEC 1034 part 1 and 2 95% light transmittance Flame Propagation - Bunched Cable ( d≥ 12mm) IEC 60332-3-24 Max. burn length 2.5m
3
Halogen content DIN VDE 0472 pt 815 Non-detected Flame Propagation - Bunched Cable (>6mm/<12mm) EN 50305 Clause 9.1.1 Max burn length 2.5m
Corrosivity of combustion gasses DIN VDE 0472 part 813, IEC 754-2 5.0 pH, <4 µS/mm conductivity Flame Propagation - Bunched Cable (d ≤6mm) EN 50305 Clause 9.1.2 Max burn length 1.5m
< 15 sec after burn Smoke Testing EN 61034-2 3m cube 90% min. transmittance 4
Flammability VG 95218 part 2
< 150 mm burn length
Toxicity EN 50305 Clause 9.2 Index max.6
Fluorine Content IEC 60684-2 CI 45.2 <0.1% Fluorine 5
Evolution of HCL EN 60754-1 <0.5% HCL
Acid Gas Emission EN 60754-2 pH >4.3 conductivity <10µS/mm 6
100E EN50306-2 Thin Wall Single Core Wires 300 volts 7
Conductor Finished Wire Conductor Finished Wire
Cross Conductor Max. Cross Conductor Max. 8
Max. Max. Max. Max. Max. Max.
Part Description Sectional Stranding Resistance @ Part Description Sectional Stranding Resistance @
Diameter Diameter Weight Diameter Diameter Weight
Area No./Diam 20ºC Area No./Diam 20ºC
9
100G0111-0.15-* 0.15 mm 2 19/0.10 mm 0.50 mm 133.0 Ω/km 1.08 mm 2.59 kg/km 100E0111-0.50-X 0.50 mm 2 19/0.18 mm 0.90 mm 40.1 Ω/km 1.45 mm 6.60 kg/km
100E0111-0.75-X 0.75 mm 2 19/0.23 mm 1.15 mm 26.7 Ω/km 1.65 mm 8.90 kg/km
100G0111-0.25-* 0.25 mm 2 19/0.13 mm 0.63 mm 83.3 Ω/km 1.19 mm 3.59 kg/km
10
100E0111-1.00-X 1.00 mm 2 19/0.25 mm 1.26 mm 20.0 Ω/km 1.80 mm 10.7 kg/km
100G0111-0.40-* 0.40 mm 2 19/0.16 mm 0.79 mm 50.5 Ω/km 1.38 mm 5.18 kg/km
100G0111-0.50-* 0.50 mm 2 19/0.18 mm 0.90 mm 40.1 Ω/km 1.45 mm 6.60 kg/km 100E0111-1.50-X 1.50 mm 2 37/0.23 mm 1.58 mm 13.7 Ω/km 2.13 mm 16.0 kg/km
100G0111-0.60-* 0.60 mm 2 19/0.20 mm 1.01 mm 31.1 Ω/km 1.57 mm 7.40 kg/km 100E0111-2.50-X 2.50 mm 2 37/0.29 mm 2.01 mm 8.21 Ω/km 2.63 mm 25.7 kg/km 11
100G0111-0.75-* 0.75 mm 2 19/0.23 mm 1.15 mm 24.7 Ω/km 1.65 mm 8.90 kg/km
12
100G0111-1.00-* 1.00 mm 2 19/0.25 mm 1.26 mm 20.0 Ω/km 1.80 mm 10.70 kg/km 100E EN50306-3 Single Core Cables, Screened and Thin Wall Sheathed
100G0111-1.20-* 1.20 mm 2 19/0.29 mm 1.42 mm 15.3 Ω/km 1.98 mm 13.60 kg/km
Cross
100G0111-1.50-* 1.50 mm 2 37/0.23 mm 1.58 mm 12.9 Ω/km 2.13 mm 16.00 kg/km Part Description Sectional Shield Jacket Thickness Nom. Overall Max. 13
Size Min. Nom. Diameter Weight
100G0111-2.00-* 2.00 mm 2 37/0.25 mm 1.82 mm 9.8 Ω/km 2.41 mm 20.30 kg/km Area
100E1111-0.50-X 0.50 mm 2 0.10 mm 0.20 mm 0.38 mm 2.61 mm 17.4 kg/km
100G0111-2.50-* 2.50 mm 2 37/0.29 mm 2.01 mm 8.0 Ω/km 2.63 mm 25.70 kg/km 14
100G0111-3.00-* 3.00 mm 2 37/0.32 mm 2.24 mm 6.4 Ω/km 2.86 mm 31.00 kg/km 100E1111-0.75-X 0.75 mm 2 0.10 mm 0.20 mm 0.38 mm 2.82 mm 20.7 kg/km
100G0111-4.00-* 4.00 mm 2 56/0.30 mm 2.57 mm 4.9 Ω/km 3.17 mm 43.60 kg/km 100E1111-1.00-X 1.00 mm 2 0.10 mm 0.20 mm 0.38 mm 2.95 mm 23.9 kg/km
15
100E1111-1.50-X 1.50 mm 2 0.10 mm 0.20 mm 0.38 mm 3.28 mm 31.6 kg/km
100E1111-2.50-X 2.50 mm 2 0.10 mm 0.20 mm 0.38 mm 3.88 mm 49.3 kg/km
16
17
18
www.is-rayfast.com 37