Page 40 - IS-Rayfast Catalogue - Issue 9, 2017
P. 40
Wire and Cable
100E Wire
Halogen Free, Low Smoke
Fire Hazard Properties and Part Numbering
1 100E EN50306-3 Two Core Cables, Screened and Thin Wall Sheathed
Conductor Finished Wire
2
Cross
Shield Jacket Thickness Nom. Overall Max.
Part Description Sectional Size Min. Nom. Diameter Weight
3 Area
100E1121-0.50-X 0.50 mm 2 0.13 mm 0.20 mm 0.38 mm 4.14 mm 32.5 kg/km
100E1121-0.75-X 0.75 mm 2 0.13 mm 0.20 mm 0.38 mm 4.56 mm 39.0 kg/km
4
100E1121-1.00-X 1.00 mm 2 0.13 mm 0.20 mm 0.38 mm 4.81 mm 47.0 kg/km
100E1121-1.50-X 1.50 mm 2 0.13 mm 0.20 mm 0.38 mm 5.48 mm 64.4 kg/km
5
100E1121-2.50-X 2.50 mm 2 0.13 mm 0.20 mm 0.38 mm 6.48 mm 95.2 kg/km
6 100E EN50306-3 Three Core Cables, Screened and Thin Wall Sheathed
Cross
Shield Jacket Thickness Nom. Overall Max.
7 Part Description Sectional Size Min. Nom. Diameter Weight
Area
100E1131-0.50-X 0.50 mm 2 0.13 mm 0.20 mm 0.38 mm 4.36 mm 42.0 kg/km
8
100E1131-0.75-X 0.75 mm 2 0.13 mm 0.20 mm 0.38 mm 4.82 mm 52.2 kg/km
100E1131-1.00-X 1.00 mm 2 0.13 mm 0.20 mm 0.38 mm 5.09 mm 62.3 kg/km
9
100E1131-1.50-X 1.50 mm 2 0.13 mm 0.20 mm 0.38 mm 5.81 mm 85.9 kg/km
100E1131-2.50-X 2.50 mm 2 0.13 mm 0.20 mm 0.38 mm 6.86 mm 129 kg/km
10
100E EN50306-3 Four Core Cables, Screened and Thin Wall Sheathed
11
Cross
Part Description Sectional Shield Jacket Thickness Nom. Overall Max.
12 Area Size Min. Nom. Diameter Weight
100E1141-0.50-X 0.50 mm 2 0.13 mm 0.25 mm 0.38 mm 4.72 mm 85.8 kg/km
13 100E1141-0.75-X 0.75 mm 2 0.13 mm 0.25 mm 0.38 mm 5.22 mm 101 kg/km
100E1141-1.00-X 1.00 mm 2 0.13 mm 0.30 mm 0.43 mm 5.62 mm 123 kg/km
14 100E1141-1.50-X 1.50 mm 2 0.13 mm 0.38 mm 0.48 mm 6.53 mm 168 kg/km
100E1141-2.50-X* 2.50 mm 2 0.13 mm 0.46 mm 0.61 mm 7.96 mm 250 kg/km
15
16
17
18