Page 258 - IS-Rayfast Catalogue - Issue 9, 2017
P. 258

Terminals and Splices
      Shield Termination
      SolderSleeve ®
      Heat Shrinkable, Shield termination

  1   Product Selection Process
       1  Select product series from the  Product
         Series Selection Guide on previous page.
  2    2  Determine cable dimensions for Jacket OD
         and Shield OD.
       3  Optional: Select pre-installed wire lead
  3
         type from the table below.                                               Only B-155, SO96, SO175 and S200X RoHS
       4  Select part number from the product
  4      selection tables on the following pages.
                                           RoHS
  5                                        compliant                               compliant


  6   Pre-installed Lead Description
                                                             Length
      Product Series    Approval     Type      Plating  AWG   Min.     Colour
  7
      S200            SAE-AS83519  M22759/91   Silver   22   150mm     White
      ST18, ST63       NAS 1747     55A0111     Tin    20-26
  8
      SO63            SAE-AS83519   55A0111     Tin    20-26
                                                             150mm    White/Black
      S02               M83519      55A0111     Tin    20-26
  9
      SO96, SO175     SAE-AS83519   55A0813    Nickel   22
      B-151              LFH       100G0111     Tin     18   150mm     White
  10  B-155              RoHS    XL polyethylene  Tin   22
                                                             150mm  White & Green
      CWT              Commercial  XL polyethylene  Tin  22
  11  SO63, SO96, SO175  SAE-AS83519  Braid Strap  Nickel  22
      SO3              Commercial  Braid Strap  Tin/Nickel  22  150mm  Un-insulated
  12  S200            SAE-AS83519  Braid Strap  Nickel  22


  13

                                                     Jacket OD (A)
  14 Product Selection Tables:
                                                                    Insulation OD (C)
      Please see the following tables for part number
  15  cross reference for given size of cable jacket
      Ø (A); Shield Ø (B) and Insulation Ø (C). Please
      contact us for more information or advice on
  16  correct product if required.

                                                             Shield OD (B)
  17
      Note:
  18   •  Heat guns are recommended for the installation of all these devices on the following pages: HL2010E and
         CV198X with the correct reflector added. See Application Equipment Section.