Page 216 - IS-Rayfast Catalogue - Issue 9, 2017
P. 216
Moulded Parts
101A011 to 094 As supplied
End Caps - Standard Wall
Heat shrinkable
1 Provide optimum water-proofing and H Dia.
environmental protection for underwater,
underground, or outdoor applications. Highly
2 resistant to moisture, fungus and weathering.
Used for protecting cable and pipes, or
capping unused outlets in transitions, providing
3 an environmental seal when used with
adhesive. After Recovery
4 Ordering Information
• Size selection please refer to table below.
• When ordering specify the product name,
5
size, material, coating, as per Part Number
H Dia.
System.
6 • Adhesive coating is optional. If added
the entry dimensions will be reduced by
1.5mm. RoHS HW P
7 compliant
8 Product Dimensions Selection Table
Dimensions as Supplied Dimensions After Recovery
9 Dimension H H P Nom. HW ±20%
Part Number
101A011 5.1 2.00 22.90 1.02
10
101A021 7.40 3.30 25.40 1.27
101A031 10.20 4.80 30.50 1.52
11
101A041 15.20 6.40 40.60 1.78
101A062 25.40 11.40 68.80 2.29
12
101A083 50.80 22.90 101.60 2.79
101A094 83.80 38.10 114.30 3.05
13
All dimensions in mm unless otherwise stated
14
Materials Available Environmental Adhesives Available
15
Material Material Description Optional Pre-coat Optional User Applied
-3 Semi-rigid polyolefin /42 or /86 S-1017 or S-1048
16 -4 Flexible polyolefin /42 or /86 S-1017 or S-1048
-12 Fluoro-elastomer N/A S-1255-04
17 -25 Fluid resistant elastomer /42 or /86 or /225 S-1017 or S-1048 or S-1125
-100 Polyolefin, Zerohal /86 or /180 S-1048 or S-1030
18
For more information on materials and adhesives, please refer to relevant sections of this catalogue.
214 sales@is-rayfast.com | +44(0)1793 616700